Tel Number
180-3717-8440
Model:KJ-TCVD1100-S60CK1
Description:
The CVD system uses a gaseous compound or a mixture of compounds to undergo a chemical reaction on the heating surface of the substrate. It is a film material preparation system that generates a non-volatile coating on the surface of the substrate , which
Product name | CVD Chemical Vapor Deposition System | |
Product model | KJ-TCVD1100-S60CK1 | |
Heating Furnace system |
||
Slide rail | With sliding rail to achieve rapid heating or cooling | |
Heating zone | 400mm | |
Tube size | 60 mm x1400mm outer diameter x length | |
Tube material | High purity quartz tube | |
Working temperature | ≤ 1100°C | |
Temperature control | Intelligent 30-segment PID microcomputer programmable automatic control | |
Temperature control accuracy | ±1℃ ( with over-temperature and Thermocouple-broken alarm function) | |
heating rate | Suggest 0~10℃/ min | |
heating element | Resistance wire | |
Rated voltage | Single phase 220V 50Hz | |
Permeable gas | gases such as nitrogen and argon | |
Temperature measuring element | Thermocouple temperature measurement | |
Shell structure | Double shell structure with air cooling system | |
Vacuum flange | Flange end with 1/4" tube fitting inlet, 60 mm flange. | |
Gas mixing station system | ||
Mass Flowmeter |
Four-way precision MFC flowmeter: Measurement accuracy: ±1.5% FS Flow range: : 0~200 sccm (based on customer’s requirement ) Flow range: : 0~200 sccm (based on customer’s requirement ) Flow range: : 0~2 00 sccm (based on customer’s requirement) Flow range: : 0~500 sccm (based on customer’s requirement ) Adjust gas flow via touch screen |
Vacuum System | |
vacuum system | Rotary vane pump, the vacuum degree can reach 1pa in the cold state of the empty furnace, Vacuum gauge: Imported digital display vacuum gauge displays vacuum degree in real time with high precision. |
Pressure Control System | |
Control Range | Overall controllable pressure range -20kpa to 20kpa (relative pressure) Or based on your requirement. |
Others | |
Automation control 1 5 ” touch screen | Touch screen interface integrated control furnace, vacuum pump, mass flow meter and pressure control system . The furnace part needs to set up the temperature time curve first. The integrated control section can control Start and stop of temperature curve, vacuum degree, gas flow, pressure relief valve, etc. |
Standard accessories |
1 digital vacuum gauge, 1 pair of quartz furnace plugs, 1 pair of high-sealing flanges, fluorine rubber sealing ring 2 pairs, 1 high-temperature crucible hook, 1 hex wrench for disassembling the flange, warranty card instruction manual 1 copy |